Home / Products / Thermocouple / Compensating Wire
열전대·보상도선

Thermocouple / Compensating Wire

Compensating and extension wires connect a thermocouple to its reference junction. Select conductor materials and temperature ranges for the thermocouple type.

1. Application

1) With insulated on a pair of conductors almost same EMF with thermocouple from low temperature to high temperature,
    Connect between the terminal of thermocouple and measuring point with wire.
    To compensate error of temperature change on terminal of thermocouple is Compensating Wire.
2) The wire made by same material of thermocouple is called Extension Wire.

  • Thermocouple / Compensating Wire
  • Thermocouple / Compensating Wire
  • Thermocouple / Compensating Wire

2. Thermocouple Wire Type

Thermocouple Type and Material
KS C 1602
Thermocouple Wire Type and Material ( KS C 1609 ) SymbolISA-MC 96.1-1982 (ANSI MC 96.1)
Material of PoleSegmentationTemp. Range(℃)Tolerance Temp. Range(℃)Tolerance
TypeEx. SymbolMaterialPositive(+)Negative(-)NormalPrecise NormalPrecise
B-Platinum Rhodium 30%
Platinum Rhodium 6%
SCR
COPPER
SCR
COPPER
G0~100 - - BC0~100+0.000㎷
-0.033㎷
-
R -Platinum Rhodium 13%
Platinum
SCR
COPPER
COPPER
NICKEL
ALLOY
G 0~150+3
-7
-

RX

SX

0~200±0.057
㎷(±5)
-
S -Platinum Rhodium 10%
Platinum
H
KCACHROMEL
ALUMEL
CHROMELALUMELG -20~150± 2.5± 1.5 KX0~200± 2.2-
H
WIRON
W-CONSTANTAN
IRONW-CONSTANTANG -20~150± 3 - WX - - -
H
VCOPPER
V-CONSTANTAN
SCR
COPPER
V-CONSTANTAN G -20~100± 2.5 - VX - - -
ECRCCHROMEL
E-CONSTANTAN
CHROMELE-CONSTANTANG-20~150± 2.5 - EX0~200± 1.7 -
H
JICIRON
J-CONSTANTAN
IRONJ-CONSTANTANG-20~150± 2.5 - JX0~200± 2.2± 1.1
H
T CCCOPPER
T-CONSTANTAN
COPPERT-CONSTANTANG-20~150 ± 2.0 ± 1.0 TX-60~100± 1.0± 0.5

3. Properties per materials

Insulation MaterialSymbolTemp. Range(℃)Water ResistanceOil ResistanceSolvent ResistanceInsulation Resistance(MΩ/Km)
PVC V-20~60○△△60
Heat Resistant PVC HV-20~105○△△60
PE E-60~60○△X2,500
XLPE C-60~125○△X2,500
PET P60~150◎◎◎ 1,500
EP EP-40~80△X△80
Nylon N-40~120◎◎◎1,500
Polyimide PI-250~300◎◎◎1,500
Teflon F-100~250◎◎◎1,500
Silicone Rubber K-60~200○X○80
E-Glass G-73~480 X△○0.1
S-Glass S-73~705X△○0.1
Ceramic Fiber --18~1205X△○0.1

4. Description and code of Thermocouple Extension wire

Thermocouple / Compensating Wire
1) Type2) Segmentation3) Material of Insulation and Sheath4) Shield Type 5) Shape6) Cores Coposition7) Conductor size and Composition
KX, JX, EX,
TX, NX, SX
G : General Normal
H : Heat Resistant
      Normal
GS : General Precise
HS : Heat Resistant
       Precise
V : Vinyl
HV : Heat resistant
       Vinyl
F : Teflon ( FEP )
G : Glass Fiber
SB : Tin Coated
       Copper Braiding
AL : Aluminum Mylar
       Tape
CU : Copper Tape
F : Flat Type
R : Round Type
3P : 3 Pair