Internal wiring of Home Appliance, Heating Equipment and Kitchenware
Internal wiring of Lighting Equipment, Motor Lead and Office Equipment
Internal wiring of Boiler, Industrial Machinery, Telecommunication Equipment
Evenly insulated on conductor followed concentric circle as specified thickness in below table.
* Insulation material : FEP (200℃), PFA (250℃), ETFE (150 or 200℃)
1) Good for extreme low temperature and Heat Resistance (-50℃ ∼ 250℃)
2) Good electrical insulating characteristics with low, nearly frequency-independent
Dielectric characteristics
3) Excellent Dielectric Strength and Mechanical Properties
4) Excellent Oil Resistance, Chemical Resistance, Solvent Resistance
5) Flame Retardant and Self-extinguishing
Items | FEP | PFA | ETFE | |||
---|---|---|---|---|---|---|
Dielectric Strength | General | Shall withstand without breakdown at AC 2,000V / 1min | - | - | ||
UL | METHOD Ⅰ | 1)Shall withstand without breakdown at AC 2,000V / 1min 2)BDV after aging should be more than 50% of before aging. | ||||
METHOD Ⅱ | Shall withstand without breakdown at AC 2,000V / 1min before/after aging | |||||
METHOD Ⅲ | Shall withstand without breakdown at AC 2,000V / 1min | |||||
Physical Properties of Insulation | Un-Aged | Tensile strength | More than 1.76 Kgf/mm2 | More than 1.76 Kgf/mm2 | 150℃ | More than 3.52 Kgf/mm2 |
200℃ | More than 1.41 Kgf/mm2 | |||||
Elongation | More than 200% | More than 200% | 150℃ | More than 100% | ||
200℃ | More than 200% | |||||
Aged | Tensile strength | More than 75% | More than 85% | 150℃ | More than 85% | |
200℃ | More than 80% | |||||
Elongation | More than 75% | More than 85% | 150℃ | More than 75% | ||
200℃ | More than 85% | |||||
Heat Shock | Specimen shall not show evidence of cracking | |||||
Cold Bend | Specimen shall not show evidence of cracking | |||||
VW-1 | 1) The insulated wire shall not combustible materials in its vicinity. 2) The indicator flag shall not ignite more than 25% in its area. |
1) Internal Specification ( 300V FEP:200℃, PFA:250℃, ETFE:150 or 200℃ )
Conductor | Insulation | Conduct Resistance (Ω㎞,25℃) | Test Voltage (SPARK) (AC V) | |||
---|---|---|---|---|---|---|
Cross-sectional Area(㎟) | Composition(Cores/㎜) | Diameter(㎜) | Thickness(㎜) | Standard Diameter(㎜) | ||
0.05 | 7 / 0.102 | 0.31 | 0.15 | 0.61 | 364 | 2,000 |
0.09 | 7 / 0.127 | 0.38 | 0.18 | 0.74 | 226 | 2,000 |
0.14 | 7 / 0.16 | 0.48 | 0.20 | 0.88 | 141 | 3,000 |
0.2 | 7 / 0.203 | 0.61 | 0.20 | 1.01 | 87.9 | 3,000 |
11 / 0.16 | 0.61 | 0.26 | 1.13 | 85.5 | 3,000 | |
0.3 | 12 / 0.18 | 0.72 | 0.26 | 1.25 | 54.8 | 3,500 |
60 / 0.08 | 0.74 | 0.30 | 1.34 | 55.6 | 3,500 | |
3 / 20 / 0.08 | 0.74 | 0.30 | 1.34 | 56.0 | 3,500 | |
7 / 21 / 0.05 | 0.78 | 0.30 | 1.38 | 59.2 | 3,500 | |
0.5 | 20 / 0.18 | 0.94 | 0.26 | 1.46 | 39.6 | 3,500 |
7 / 0.32 | 0.96 | 0.25 | 1.46 | 34.4 | 3,500 | |
0.75 | 30 / 0.18 | 1.15 | 0.28 | 1.71 | 25.8 | 4,000 |
1.25 | 50 / 0.18 | 1.48 | 0.30 | 20.7 | 15.5 | 4,000 |
7 / 22 / 0.08 | 1.30 | 0.35 | 2.00 | 18.8 | 4,000 | |
2.0 | 37 / 0.26 | 1.83 | 0.31 | 2.45 | 9.63 | 4,000 |
3.5 | 45 / 0.32 | 2.60 | 0.35 | 3.30 | 5.38 | 4,000 |
5.5 | 35 / 0.45 | 3.07 | 0.40 | 3.90 | 3.47 | 4,000 |
68 / 0.32 | 3.40 | 0.40 | 4.18 | 3.50 | 4,000 | |
8.0 | 50 / 0.45 | 3.70 | 0.60 | 4.50 | 2.67 | 4,000 |
99 / 0.32 | 4.10 | 0.47 | 5.09 | 5.75 | 4,000 | |
14 | 7 / 25 / 0.32 | 5.0 | 0.50 | 6.00 | 1.27 | 5,000 |
22 | 7 / 39 / 0.32 | 6.14 | 0.70 | 7.54 | 0.81 | 5,000 |
38 | 7 / 34 / 0.45 | 8.0 | 0.70 | 9.40 | 0.489 | 5,000 |
50 | 19 / 16 / 0.45 | 10.4 | 0.8 | 12.0 | 0.441 | 5,000 |
* Solid Conductor product is also available from 0.26mm~1.40mm.
2) UL Specification
UL Style | Rating | AWG No | Insulation | Remark | ||
---|---|---|---|---|---|---|
Temperature | Voltage | Meterial | Thickness(mm) | |||
1330 | 200℃ | 600V | 30 - 4/0 | FEP | 0.51 | |
1331 | 150℃ | 600V | 30 - 4/0 | FEP | 0.51 | |
1332 | 200℃ | 300V | 30 - 10 | FEP | 0.33 | |
1333 | 150℃ | 300V | 30 - 10 | FEP | 0.33 | |
1726 | 250℃ | 300V | 30 - 4/0 | PFA | 0.33 | |
1727 | 250℃ | 600V | 32 - 4/0 | PFA | 0.51 | |
10125 | 150℃ | 300V | 36 - 4/0 | ETFE | 0.15 | |
10142 | 250℃ | 600V | 24 - | PFA | 0.56 | Heating Wire |
10617 | 150℃ | 300V | 40 - 4/0 | FEP | 0.15/0.15 | 2 layer |
We certify that there is not contained Hazardous substances in this product such as Lead(Pb), Mecury (Hg), Cadmum (Cd), Hexavalent Chromium(Cr+6), PPB, PBDE.