Internal wiring of Home Appliance, Heating Equipment and Kitchenware
Internal wiring of Lighting Equipment, Motor Lead and Office Equipment
Internal wiring of Boiler, Industrial Machinery, Telecommunication Equipment
1) Conductor : Tin Coated Copper / Nickel Plated Copper
2) Insulation : Silicone Rubber
1) Good Heat Resistance, Cold Resistance, Weather Resistance and electrical insulating properties
2) Divided High tearing Resistance, High Voltage, Ultra Heat Resistance type according to application
3) Reinforced Type : Sheathed Teflon Resin and other organic resin on silicone insulation
to increase mechanical Strength and oil resistance, solvent resistance
Test Item | General | UL | CSA | ||
---|---|---|---|---|---|
STANDARD | 【 KS C 3004 】 Rubber ․ Plastic Insulation Cable Test Method | 【 UL 758 】 APPLIANCE WIRING MATERIAL | 【 C22.2 No. 127 】 EQUIPMENT WIRE | ||
Dielectric Strength Test | Shall withstand without breakdown at AC 2KV/1 Min. | 1) Shall withstand without breakdown at AC 2KV/1 Min. before/after aging 2) Not less than 50% |
Shall withstand without breakdown at AC 2KV/1 Min. | ||
Physical Properties of Insulation | Un-aged | Tensile Strength | Not less than 0.40kgf/㎟ | Not less than0.352kgf/㎟ | Not less than 0.489kgf/㎟ |
Elongation | Not less than 150 % | Not less than 100% | Not less than 100% | ||
Aged | Tensile Strength | 1) Not less than 70% 2) Not less than 0.352kgf/㎟ |
1) Not less than 60% 2) Not less than 0.352 kgf/㎟ |
Not less than 0.347kgf/㎟ | |
Elongation | 1) Not less than 60% 2) Not less than 100% |
1) Not less than 25% 2) Not less than 50% |
Not less than 50% | ||
Heat Shock Test | Shall not show evidence of cracking of insulation and braiding |
- | Shall not show evidence of cracking of insulation and braiding | ||
Flexibility Test in the air oven | - | Shall not show evidence of cracking of insulation and braiding | - | ||
Cold Bend Test | Shall not show evidence of cracking of insulation and braiding | Shall not show evidence of cracking of insulation and braiding |
Shall not show evidence of cracking of insulation and braiding | ||
Horizontal Flame Retardant Test | Flame in specimen shall not be continued more than 1 Min. and shall not be combustive of whole 300㎜ of specimen | 1) Shall not convey flame to combustible materials in its vicinity 2) Shall not convey flame to it length at a flaming rate greater the 25㎜/1min |
Shall not be combustive more than 100㎜. |
1) Internal Specification
Conductor | Insulation Thickness(㎜) | Overall Diameter (㎜∮) | Remark | |||
---|---|---|---|---|---|---|
Cross-sectional Area(㎟) | Composition(cores/㎜φ) | Diameter | Resistance(Ω/∮) | |||
0.10 | 51 / 0.05 | 0.4 | 188.93 | 0.40 | 1.20 ± 0.10 | |
0.15 | 30 / 0.08 | 0.5 | 123.82 | 0.40 | 1.30 ± 0.10 | |
0.20 | 3 / 34 / 0.05 | 0.7 | 95.10 | 0.40 | 1.50 ± 0.10 | |
0.30 | 3 / 51 / 0.05 | 0.8 | 63.40 | 0.40 | 1.60 ± 0.10 | |
0.30 | 3 / 20 / 0.08 | 0.8 | 61.96 | 0.54 | 1.80 ± 0.10 | |
0.30 | 12 / 0.18 | 0.7 | 64.40 | 0.40 | 1.50 ± 0.10 | |
0.37 | 7 / 0.26 | 0.8 | 50.37 | 1.16 | 3.10 ± 0.15 | |
0.40 | 3 / 70 / 0.05 | 1.0 | 46.20 | 0.40 | 1.80 ± 0.10 | |
0.45 | 90 / 0.08 | 0.9 | 38.89 | 0.40 | 1.70 ± 0.10 | |
0.45 | 3 / 30 / 0.08 | 1.0 | 38.89 | 0.36 | 1.80 ± 0.10 | |
0.48 | 96 / 0.08 | 0.9 | 36.46 | 1.15 | 3.20 ± 0.15 | |
0.50 | 3 / 33 / 0.08 | 1.1 | 38.30 | 0.40 | 1.90 ± 0.10 | |
0.50 | 1 / 0.80 | 0.8 | 35.75 | 0.70 | 2.20 ± 0.10 | |
0.50 | 20 / 0.18 | 0.8 | 37.17 | 0.38 | 1.70 ± 0.10 | |
0.60 | 4 / 35 / 0.08 | 1.2 | 25.00 | 0.60 | 2.40 ± 0.10 | |
0.64 | 12 / 0.26 | 1.0 | 29.38 | 0.98 | 3.00 ± 0.10 | |
0.70 | 62 / 0.12 | 1.1 | 25.10 | 1.27 | 3.80 ± 0.10 | |
0.75 | 3 / 50 / 0.08 | 1.3 | 25.30 | 0.40 | 2.10 ± 0.10 | |
0.75 | 30 / 0.18 | 1.2 | 24.78 | 1.93 | 5.00 ± 0.20 | |
0.78 | 154 / 0.08 | 1.1 | 22.73 | 1.42 | 4.00 ± 0.20 | |
0.88 | 7 / 0.40 | 1.2 | 21.28 | 1.90 | 5.00 ± 0.20 | |
0.89 | 35 / 0.18 | 1.3 | 21.24 | 0.49 | 2.20 ± 0.10 | |
1.00 | 40 / 0.18 | 1.3 | 17.00 | 3.35 | 8.0 ± 0.20 | for Ignition |
1.05 | 7 / 30 / 0.08 | 1.5 | 16.67 | 0.74 | 3.00 ± 0.15 | |
1.25 | 3 / 36 / 0.08 | 1.6 | 15.00 | 0.40 | 2.40 ± 0.10 | |
1.25 | 50 / 0.18 | 1.5 | 14.87 | 0.52 | 2.50 ± 0.10 | |
1.69 | 7 / 48 / 0.08 | 1.9 | 10.42 | 1.04 | 4.00 ± 0.20 | |
2.00 | 7 / 57 / 0.08 | 2.0 | 9.49 | 0.50 | 3.00 ± 0.10 | |
2.00 | 37 / 0.26 | 1.8 | 9.53 | 1.09 | 4.00 ± 0.20 | |
2.09 | 7 / 38 / 0.10 | 2.1 | 8.42 | 0.51 | 3.20 ± 0.15 | |
3.50 | 7 / 10 / 0.08 | 2.7 | 5.41 | 0.50 | 3.70 ± 0.15 | |
3.50 | 44 / 0.32 | 2.5 | 4.91 | 0.65 | 4.00 ± 0.20 |
2) UL Specification
ULStyle | Rating | AWG No | Insulation Thickness | Remark | |
---|---|---|---|---|---|
Temperature | Voltage | ||||
3132 | 150℃ | 300V | 30 - 16 | over 0.38 | |
3133 | 150℃ | 600V | 30 - 16 | 0.76 | |
3135 | 200℃ | 600V | 26 - 12 | 0.76 | |
3139 | 200℃ | 600V | 26 - 12 | 1.10 | |
3239 | 150℃ | DC 3KV | 27 - 10 | 0.50 | |
3239 | 150℃ | DC 6KV | 27 - 10 | 0.71 | |
3367 | 200℃ | 300V | 26 - 28 | 0.38 | |
3512 | 200℃ | 600V | 20 - 450kCmils | 0.76 |
We certify that there is not contained Hazardous substances in this product such as Lead(Pb), Mecury (Hg), Cadmum (Cd), Hexavalent Chromium(Cr+6), PPB, PBDE.